Medisafe SI PCF Manuals & User Guides. User Manuals, Guides and Specifications for your Medisafe SI PCF Laboratory Equipment. Database contains 1 Medisafe SI PCF Manuals (available for free online viewing or downloading in PDF): Operation & user’s manual. The SI PCF is equipped with a fully locking lid, meaning that the process will automatically halt and re-set if the lid is opened mid-cycle. This important safety feature is designed not only to protect the integrity of the cleaning parameters, but also to minimize the risk of cross infection. Comprehensive Review 1 1956 Evinrude 10 Hp Outboard Repair Manual Medisafe Pcf Service Manual - umtinam.com Yamati Eurostrada Owner Manual - orrisrestaurant.com Evga Geforce Gtx 295 Co Op Edition calendar.pridesource Avalon Squib Circuit Pdfslibforme calendar.pridesource Le Pi Facili Composizioni Laying. We recommend that you read this manual before operating the Medisafe refrigerator and retain it for future reference. Contact Information Should you require assistance, guidance or technical support, please contact: Quirks Australia Pty Ltd. (Head Office) 198 Power Street Glendenning NSW 2761 Phone: 1800 686 672 (24 Hour National Service Support).
DESCRIPTION
Validated for cleaning and thermal disinfection of daVinci® EndoWrist® instruments.The Medisafe Sonic Irrigator (SI) PCF automated cleaning system is validated for cleaning and thermal disinfection of daVinci® EndoWrist® instruments.
Medisafe Sonic Irrigator “PCF”- is the most versatile instrument cleaning system available today. Now available as purchase option, thermal disinfection for complex cannulated instruments both inside and out, in a fully validated and tested process. (See disinfection model option below)
Cleaning then disinfecting up to 20 standard lumened instruments at temperatures up to 195ºF both inside and out, in approximately 45-minutes per cycle.
Through our dedicated daVinci cycle, the SI PCF system offers an efficient and convenient way to clean up to 10 EndoWrist instruments simultaneously. For daVinci customers with EndoWrist instruments the Medisafe SI-PCF systems can perform both qualified cleaning along with disinfection by simply selecting “cycle #6” on systems digital display. For the qualified EndoWrist cleaning cycle without disinfection, select “cycle #3”.
Thermal disinfection for EndoWrist instruments may not be available in all countries.
Other unique feature of the SI-PCF system; automatic fill, auto pre-washing, auto enzyme injection, auto high volume sonic-flushing wash, auto high volume sonic-rinsing, auto drain. .... OR.... to add maximum versatility when needed, simply use the PCF system in a 'sonic only mode' as you would a standard ultrasonic system for walk up convenient use for cleaning basic instruments and trays.
Service Manual Bmw
FORUMSView All (7)
Ask a New Question0Replies7 months ago | 7 months agoCalibration Can someone please advise how to adjust the calibration for the detergent, after 4 years, yes 4 years, the dosage calibration has wandered!Reply |
-KC Trading 2 years ago | 2 years agoService and repair I have replaced the pump on the machine and still cannot get it to work. What else should i look at.Reply |
0Replies5 years ago | 5 years agodisplay screen does not stay on The display screen periodically blinks off. The unit still functions during this time. Reply |
VIDEOS
SPECIFICATIONS
Height | 41 in |
Length | 35.5 in |
Weight | 587.7 lbs |
Width | 26 in |
Medisafe Pcf Service Manual Instructions
Additional Specifications
Medisafe Pcf Service Manual User
For indoor use at altitudes up to 2000m / 6000ft
Operating temperature -5°C / 23°F to 91°C / 195°F
Humidity -80% RH max for temperatures up to 31°C / 88°F,
decreasing linearly to 50% RH at 40°C / 104°F
Designed for Pollution Degree 2, i.e. not totally sealed.